l
The X-BUS Settings, Retries, must be set to a value of 10.
l
The X-BUS Settings, Comms timer, must be set to a value of 5.
l
DO NOT select the attribute Setting State in the Keypad configuration settings for Visual
indications.
l
Select Network Time Protocol to specify that the time is synchronized with the specified NTP
server
Hardware Requirements
l
The back tamper kit (SPCY130) must be installed for panels and power supplies for
compliance with EN50131 Grade 3.
l
EN50131 Grade 3 compliant components must be installed for EN50131 Grade 3 compliant
systems.
l
Either EN50131 Grade 2 or 3 compliant components must be installed for EN50131 Grade 2
compliant systems.
l
Glassbreak must be used with an EN-compliant glassbreak interface.
l
To comply with EN50131-3:2009, do not set or unset the system using the SPCE120 (Indicator
Expander) or the SPCE110 (Keyswitch Expander).
The SPCN110 PSTN module, the SPCN320 GSM/GPRS module, and the SPCN342 are tested
with EN50131 approved Grade 2 and Grade 3 panels and can be used with these approved
panels.
3.4 Compliance with EN 50136-1:2012 and EN 50136-2:2014
SPC products listed have been tested according to EN 50136-1:2012 and EN 50136-2:2014.
3.5 Compliance with INCERT Approvals
Software Requirements
Selecting Belgium (*) under Region implements local or national requirements which supercede
EN50131 requirements.
Selecting Grade 2 or Grade 3 selects EN50131 compliance plus any additional INCERT
requirements:
l
Only an engineer can restore a tamper. For INCERT, this applies across all grades.
This is normally only a requirement for Grade III En50131.
l
A tamper on an Inhibited/Isolated zone must be sent to an ARC and displayed to the user.
For INCERT, tampers are processed for isolated zones. On all other standard variations,
tampers are ignored on isolated zones.
l
User PIN codes must be defined with more than 4 digits.
Hardware Requirements
l
Minimum battery capacity for the SPC42/43/53/63 is 10Ah/12V. If a 10Ah battery is used, then
the battery is biased to the left of the housing and the bottom flap is bent to meet the battery.
l
Fit jumper (J12) on the battery selector for 17/10Ah battery use and remove for 7Ah battery.
SPC42/52/53/63 – Installation & Configuration Manual Directives and standards
© Vanderbilt 2023 19 I-200572