WIRELESS
LOST
Enable to send a Wireless Lost event over CID/SIA and FLexC on loss
of wireless signal.
SUPERVISION
TIME
Browser option is Supervision ("Two way Wireless Supervision time in
minutes")
EXTERNAL
ANTENNA
Enable an external antenna.
SUPERVISION Enable tamper supervision. Browser option is Missing Supervision
("Select whether missing supervision for a sensor will raise a zone
tamper")
RF FOB SOS Disable the RF FOB SOS or specify the panel action from the following
options: PANIC, PANIC SILENT, USER MEDIC, USER HOLDUP, RF
OUTPUT.
WPA TEST
SCHED.
Enter a maximum period (in days) between WPA tests. Max is 365 days,
0 days means that the WPAtest disabled.
PREVENT SET
TIME
Enter a time in minutes after which, if the sensor or WPA fails to report,
setting is prevented for the area where the wireless zone is. Max is 720
minutes, 0 minutes means that checking is disabled.
DEVICE LOST
TIME
Enter the number of minutes after which the wireless device is reported
as lost if it fails to report within this time frame. (Min is 20 and max is 720
minutes. 0 means that checking is disabled.)
1
A WPA is compatible with SiWay RF Kit (SPCW120 or WRTX) only.
14.9.2 Two way wireless
The following devices can be enrolled on a two way wireless transceiver:
l
Wireless sensors (motion detectors, magnetic contacts, smoke alarms)
l
Wireless outputs (internal and external sirens)
l
Wireless repeaters
l
Wireless keypads
l
WPAN personal alarm button
l
WRMT remote control
Please note that you must enable two way wireless before enrolling these devices.
To enable two way wireless:
1. Scroll to WIRELESS and press OK.
2. Scroll to SETTINGS and press OK.
3. Scroll to 2 WAY WIRELESS and select ENABLE
The SPCW120 Wireless Transceiver with firmware 4.7.x or later can support up to the following number
of devices:
l
64 detectors
l
16 output sirens
l
8 wireless keypads
l
4 repeaters
l
20 fobs (personal alarm buttons and/or remote controls)
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the keypad