EasyManua.ls Logo

Acre SPC42 - Doors

Acre SPC42
297 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Performable actions
Refresh Updates the status information displayed for the panel.
Log Click the Log button to view a log of the input status of that zone.
Inhibit Click this button to inhibit a fault or open zone. The inhibit operation will disable that fault or zone for
one arming period only.
Inhibit operation is not available in Security Grade EN 50131 Grade 3.
Restore Click this button to restore the alarm condition of the panel.
Isolate Zone . Isolating a zone will deactivate that zone until such time as the zone is explicitly deisolated
again.
It is recommended that you exercise caution when isolating zones as those zones will not be active
every time the system is SET.
Soak Highlight a zone and click this button to perform a Soak test on that zone.
Seismic
Test
Click this button to initiate a test of the selected seismic sensor. For more information on seismic
sensors, see Seismic Sensors on page256.
Hide
Closed
Click this button to hide all closed inputs.
15.6.5 Doors
1. To view all doors, select Status > Doors.
The following table shows the information that is available.
Door This ID number is a unique identifier for the door.
Zone The zone number the door position sensor is attached to (only if the door position sensor input is also
used as intrusion zone).
Area The area the door position sensor input and the card reader are assigned to.
DPS Status of the door position sensor.
DRS Status of the door release switch.
Status The status of the door (OK, fault).
Door
Mode
Specifies the door operate mode.
Performable actions
Refresh Updates the door summary.
Log Displays a log of events for the selected door.
Lock Locks the selected door.
Unlock Unlocks the selected door.
Normal Returns the door to normal system control.
Momentary Unlocks the door for one timed interval.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 135 I-200572