Acre SPC42 - Wiring the Outputs

Acre SPC42
297 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Number Description
2 COM
3 Tamper
4 Alarm
5 4k7
6 Detector Fault
7 2K2
8 EOL 4k7
6.5.2 Wiring the Outputs
The expander and PSU relay logical outputs can be assigned to any of the SPC system outputs. The
relay outputs can switch a rated voltage of 30V DC at 1A (non-inductive load).
When the relay is activated, the Common terminal connection (COM) is switched from the Normally
Closed (NC) to the Normally open (NO) terminal.
The following diagram shows the wiring of an active, high output:
Number Description
1 Normally Open terminal
2 Common terminal connection (COM)
3 Normally Closed terminal (NC)
SPC42/52/53/63 Installation & Configuration Manual Mounting system equipment