Enrol a WRMT remote control
To enrol the WRMT and assign it to a User (n):
1. Select USERS > EDIT > USER (n) > RF FOB > ENABLED.
The keypad displays the ADD screen with a flashing ENROL DEVICE message.
2. On the WRMT, press and hold the two SOS buttons.
The LED blinks Red once and then Green to confirm enrolment. A message appears on the
keypad screen saying FOB CONFIGURED. The WRMT is assigned to the User (n).
Disable a WRMT remote control
To disable a WRMT:
l
Select USERS > EDIT > USER (n) > RF FOB > DISABLED.
A message appears on-screen saying UPDATED.
When you disable a WRMT from your system, you must also clear the internal registration in the WRMT
before you can re-use the WRMT.
To clear the internal registration:
l
On the WRMT, press and hold the PARTSET and UNSET buttons.
The LED blinks Red and Orange to confirm that registration is cleared.
14.10 Zones
1. Scroll to ZONES and press OK.
2. Scroll to the desired zone (ZONE 1-x).
3. Scroll to the desired programming option:
DESCRIPTION Used to help identify the zone: enter a specific and descriptive name.
ZONE TYPE Determines the zone type. See Zone types on page278.
ATTRIBUTES Determines the attributes of the zone. See Zone attributes on page283.
TO AREA Determines which zone is mapped to which area. This menu option is
only displayed if multiple areas are defined on the system. Selecting this
feature allows users to build a set of zones that are identified with a
particular area in the building.
The number and type of attributes displayed in the keypad menus for a particular zone vary
depending on the type of zone that is selected.
14.11 Doors
1. Scroll to DOORS and press SELECT.
2. Scroll to the door to be programmed and press SELECT.
3. Parameters and details, if applicable, are displayed for editing as follows:
- Description
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the keypad
© Vanderbilt 2023 99 I-200572
08.12.2023