Event Logging Options
Comms Status Log all communication availability.
EDP Commands Log all commands executed through EDP.
A/V Events Log when Audio/Video verification events are sent to Receiver.
A/V Streaming Log when Audio/Video live streaming begins.
Keypad Use Log when remote keypad is activated.
15.11.3.3 CEI-ABI Protocol Settings
1. Select Communications > Reporting > CEI-ABI.
2. Configure the fields as described in the table below.
Enable Tick this box to enable CEI-ABI support.
Connection
mode
l
Select Client to connect the panel to the CEI-ABI receiver.
l
Select Server to enable the panel to listen for connections.
Server IP If you select Client for Connection mode, enter the TCP/IP address of the
CEI-ABI receiver.
Server Port Enter the IP port for the server.
Physical
address
Enter a physical address for the CEI-ABI on the panel.
Logical
address
Enter a logical address for the CEI-ABI on the panel.
15.11.4 PC Tools
This section covers:
l
SPC Connect PRO below
l
SPC Manager on the facing page
15.11.4.1 SPC Connect PRO
SPC Connect PRO is a desktop application designed to support the installation and maintenance of
SPC systems. Using SPC Connect PRO, you can create installations and configure them prior to
arriving at site. The tool can also be used in conjunction with the SPC cloud service SPC Connect to
remotely connect to customer sites and support them.
1. Select Communications > PC Tools > SPC Connect PRO.
2. Configure the fields as described in the table below then click Save.
SPC
Connect
PRO
Tick this box to enable SPC Connect PRO to connect to the panel.
Ethernet Tick this box to allow SPC Connect PRO to connect over Ethernet.
TCP Port Enter the TCP port on which the panel listens to incoming connections from
SPC Connect PRO.
USB Tick this box to allow SPC Connect PRO to connect over USB.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser