Alarm Abort Alarm Abort events. Alarms are aborted after a valid user code is entered via
the keypad after a confirmed or unconfirmed alarm,
Faults Faults and tampers are activated.
Fault
Restores
Fault or tamper alarms are restored.
Zone state Report all zone input state changes.
Settings System is Set and Unset.
Early/Late Unscheduled setting and unsetting of the system.
Inhibits Inhibit and isolate operations are performed on the system.
Door Events Door events are activated. Only works with SIA protocol.
Other All other types of events are detected on the system.
Other (Non
standard)
Non supported SIA codes used with SPC COM XT including Camera
Online/Offline events.
Network Report IP Network Polling Up/Down events.
Areas Select specific areas to which above events apply.
Editing EDP settings
1. Select Communications > Reporting > EDP > Settings.
2. Configure the fields as described in the table below.
Enable Tick this checkbox to enable EDP operation on the system.
EDP Panel
ID
Enter a numeric identifier that is used by the EDP Receiver to identify the
panel uniquely.
Panel Port Select the IP port for receiving IP packets. Default is 50000.
Packet
Size Limit
Enter the maximum number of bytes in an EDP packet for transmission.
Event
timeout
Enter the timeout period (in seconds) between retransmissions of
unacknowledged events.
Retry
Count
Enter the maximum number or event retransmissions allowed by the
system.
Dial
Attempts
Enter the maximum number of failed dial attempts accepted by the system
before the modem is locked out (prevented from making further attempts to
dial). The lockout period is defined in the option Dial Lockout.
Dial Delay Enter the time period (in seconds) that the system will wait before redialling
after a dial attempt has failed.
Dial
Lockout
Enter the time period (in seconds) that the system will suspend dialling when
the maximum number of failed dial attempts is reached. Enter a value of ‘0’
to continually attempt dialling.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 242 I-200572
08.12.2023

Table of Contents