Dial-up Interval 1* Enter the number of minutes between dial-up test calls when
network link is up.
Dial-up Interval 2* Enter number of minutes between dial-up test calls when network
link is down.
Network Address* Enter the IP address of the receiver. This is only required if the
connection to the EDP receiver is being made over the Ethernet
interface. If using one of the on-board modems then leave this field
blank.
Phone Number* Enter the first phone number that the modem(s) will dial to contact
the receiver.
Phone Number 2* Enter a second phone number that the modem(s) will dial in the
event that the first number dialled did not result in a call being
successfully established.
Events
Primary Receiver Check this box to indicate that this is the primary receiver. If
unchecked, this is a backup receiver.
Re-queue Events Check this box if events that failed to report are to be re-queued for
transmission
Verification Check this box if Audio/Video verification is to be sent to this
receiver.
Event Filter Click this button to edit the filter events that will trigger an EDP call.
See Editing Event Filter Settings below.
* EDP dial-up over PSTN is not supported in this release.
See also
Configuring SMS on page144
Editing Event Filter Settings
1. Select Communications > Reporting > EDP > Edit > Filter.
2. Configure the fields as described in the table below.
Check any of the following boxes if you want to initiate a remote call to an EDP Receiver to notify it
of the particular event.
Alarms Alarms are activated.
Alarm
Restores
System alarms are restored.
Confirmed
Alarms
Alarms confirmed by multiple zones
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser