Reader Format
Side Code
Available
Restrictions
HID 37 No Max card no. 34359738370
HID 37F Yes Max site code. 65535
Max card no. 5242875
HID 37BCD No Max card no. 99999999
HID ICLASS MIFARE No Max card no. 4294967295
HID ICLASS DESFIRE No Encrypted card number.
Max card no. 72 x 10
16
. This number must be learned on the
panel
AR618 WIE BCD 52
BIT
No Max card no. 4294967295
AR618 OMRON 80 BIT No Max card no. 9999999999999
21.18 FlexC Glossary
Acronym EN50136-1 Description FlexC Example
AE Annunciation Equipment
Equipment located at an ARC which secures and displays the
alarm status, or the changed alarm status of ASs in response
to the receipt of incoming alarms before sending a
confirmation. The AE is not part of the ATS.
SPC Com XT Client
ARC Alarm Receiving Centre
Continuously manned centre to which information concerning
the status of one or more AS is reported.
SPC Com XT would be installed
in an ARC.
AS Alarm System
Electrical installation, which responds to the manual or
automatic detection of the presence of a hazard. The AS is not
part of the ATS.
SPC Panel
ATE Alarm Transmission Equipment
Collective term to describe SPT, MCT (Monitoring Centre
Transceiver) and RCT.
-
ATP Alarm Transmission Path
Route an alarm message travels between an individual AS
and its associated AE.
The ATP starts at the interface between AS and SPT and
ends at the interface between RCT and AE. For notification
and surveillance purposes the reverse direction may also be
used.
A defined path between the SPC
panel and SPC Com XT. For
example, system with Ethernet
as the primary path and GPRS
as a backup path would be two
separate ATPs of an ATS.
SPC42/52/53/63 – Installation & Configuration Manual Appendix
© Vanderbilt 2023 288 I-200572
08.12.2023