Acre SPC42 - Compliance with Vds 2115:2015-12; Compliance with EN50131 Approvals

Acre SPC42
297 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN50131 Requirement (and relevant section) Relevant Vanderbilt documentation
Details of any programmable facility that would render an
I&HAS non-compliant with EN 50131-1:2006, 8.3.13 or
compliant at a lower security grade, with instruction on
consequent removal of compliance labeling (see 4.2 and
8.3.10).
Unrestricted Grade on page184
Options on page169
Compliance with EN50131 Approvals below
SPC products listed have been tested according to EN50131-6, and all relevant RTC specifications.
Product Type Standard
l
SPC53
l
SPC63
l
SPC6350.320
l
SPC5350.320
l
SPCP355.300
l
SPCP333.300
l
SPCP355.300
l
SPCE652.100
l
SPCK420.100
l
SPCK421.100
l
SPCE452.100
l
SPCE110.100
l
SPCE120.100
l
SPCA210.100
l
SPCK620.100
l
SPCK623.100
l
SPCN110.000
l
SPCN310.000
EN50131-6
l
SPC52
l
SPC42
l
SPCP332.300
EN50131-6
3.3 Compliance with VdS 2115:2015-12
Only VdS-approved maintenance-free batteries may be used for as a system standby backup.
3.3.1 Compliance with EN50131 Approvals
Software Requirements
l
In the Standards settings page, select Europe under Region to implement EN50131
requirements.
l
Select Grade 2 or Grade 3 to implement the grade of EN50131 compliance.
l
The Wireless setting Prevent Setting Time must be set to a value greater than 0 and less than
20.
l
The Wireless setting Device Lost Time must be set to a value less than 120.
SPC42/52/53/63 Installation & Configuration Manual Directives and standards
© Vanderbilt 2023 18 I-200572
08.12.2023