Display
Installer
Tick this box to display the installation details on the keypad connected to the
panel when in the idle condition.
Engineer
Lock
Tick this box to require use of the engineer lock PIN to factory default the
panel.
Engineer
Lock PIN
Enter value for lock PIN (4 digits).
15.10.3.4 Standards
All alarm systems must comply with defined security standards. Each standard has specific
security requirements that apply to the market/country in which the alarm system is installed.
1. Select Configuration > System > Standards.
2. Configure the fields as described in the following table.
Continent Select the appropriate location for the installation.
Options are Europe, Asia, North America, South America, or Oceania.
Installation
Type
Select the type of installation.
Options are Domestic, Commercial or Financial.
Region
Compliance
To change the region on your panel, it is strongly recommended that you
default your panel and select a new region as part of the start up wizard.
Select the region in which the installation is installed and the regional
requirements it complies with.
Some selections will implement local or national requirements which
supersede EN50131 requirements. The options in the Grade area will
change depending on your selection in the Region Compliance area.
Options are UK, Ireland, Europe General (EN), Italy, Sweden,
Switzerland, Belgium, Spain, Germany (VDS), France, Norway,
Denmark, Poland, Netherlands, Finland, Portugal, and Czech Republic.
Grade Select the Security Grade that applies to the installation.
The options in the Grade area change depending on your selection in the
Region Compliance area.
Unrestricted Grade
A Security Grade setting of Unrestricted does not apply to any regionally approved security
restrictions of the installation. Instead, the Unrestricted setting enables an engineer to customize the
installation by changing security policy options and configuring additional options which do not
comply with the selected regional security compliance.
Unrestricted configuration options are denoted in this document by the following symbol:
See on page169 for details of configuring system policies.
15.10.3.5 Clock
This page enables you to program the date and time on the panel. The controller contains a Real-
Time Clock (RTC) that is battery-backed to preserve the time and date information in the event of
power failure.
1. Select Configuration > System > Clock.
2. Select the Time and Date from the drop down menus.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser