Timer Description Default
General Settings
RF Output Time
RF OUTPUT
The time that the RF output will remain active on the system.
(0–999 seconds)
0 sec.
Time Sync Limit
TIME SYNC LIMIT
Time limit within which time synchronization will not take
place. Time synchronization only takes place if system time
and update time are outside this limit. (0–300 seconds)
0 sec.
Link Timeout
LINK TIMEOUT
Timeout for Ethernet link fault. (0–250 seconds;
0=Disabled)
0 sec.
Camera Offline
CAMERA OFFLINE
Time for camera to go offline. (10–9999 seconds) 10 sec.
Frequent
FREQUENT
This attribute only applies to remote services. The number of
hours within which a zone must open if the zone is
programmed with the Frequent attribute. (1–9999 hours)
336 h (2
weeks)
Duress silent Time when duress will remain silent and not restorable from
keypad. (0–999 minutes)
0 min.
Holdup/panic silent Number of minutes that a holdup/panic will remain silent and
cannot be restored from the keypad. (0–999 minutes)
0 min.
Default times are dependent upon the Engineer configuration. The default times denoted may or
may not be allowable and is dependent on the configuration by the engineer.
Valid settings/ranges may be dependent on the security grade specified under Configuration >
System > Standards.
15.10.3.3 Identification
1. Select Configuration > System > Identification.
2. Configure the fields as described in the table below.
Installation
ID
Enter a unique number for each installation This number identifies the
installation (1–999999).
Installation
Name
Enter the name of the installation. An installation name must be entered
before the installation is saved on the system. The installation can be viewed
from the keypad.
Installation
Date
Select the date from the dropdown menu that the installation was completed.
Installer
Name
Enter the name of the person who installed the system (for support purposes).
Installer
Phone
Enter the contact phone number of the person who installed the system (for
support purposes).
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser