EasyManua.ls Logo

Acre SPC42 - Page 142

Acre SPC42
297 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Right
User Profile
Type
Default
Description
Fullset Limited
Standard
Manager
The FULLSET operation fully sets the alarm system and provides full protection to
a building (opening of any alarm zones activates the alarm).
On selecting FULLSET, the buzzer sounds and the keypad display counts down
the exit time period. Exit the building before this time period has expired.
When the exit time period has expired, the system is set and opening of entry/exit
zones starts the entry timer. If the system is not Unset before the entry timer
expires, the alarm is activated.
Forceset Standard
Manager
The FORCESET option is presented on the keypad display when an attempt is
made to set the system while an alarm zone is faulty or still open (the top line of
the display shows the open zone).
Selecting this option sets the alarm and inhibits the zone for that set period.
Delay Auto
Set
Standard*
Manager
User can delay or cancel autosetting.
Restore Standard
Manager
The RESTORE operation restores an alert condition on the system and clears the
alert message associated with that alert condition.
An alert condition can only be cleared after the zone(s) or fault(s) that triggered
the alert condition have been restored to their normal operating state and the
CLEAR ALERT option in user programming is selected for that zone.
Inhibit Standard
Manager
Inhibiting a zone deactivates that zone for one alarm set period.
This is the preferred method of deactivating a faulty or open zone as the fault or
open condition is displayed on the keypad each time the system is being set to
remind the user to attend to that zone.
Isolate Standard*
Manager
Isolating a zone deactivates that zone until such time as the zone is de-isolated.
All zone types on the controller can be isolated.
Use of this feature to deactivate faulty or open zones should be considered
carefully; once a zone is isolated, it is ignored by the system and could be
overlooked when setting the system in the future, compromising the security of the
premises.
User Rights - System
Web
Access
Standard*
Manager
User can access panel through web browser.
View Log Standard
Manager
This menu option displays the most recent event on the keypad display. The event
log (see Event Log on page117) details the time and date of each logged event.
Users Manager User can create and edit other users on the panel but with only the same or less
rights than this user.
SMS Standard*
Manager
This feature allows users to set up the SMS messaging service if a modem is
installed on the system.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 142 I-200572
08.12.2023

Table of Contents