Restriction System Option Description
Offline Tamper Enable this for offline expander zones to generate a zone tamper.
Keyfob Restore If enabled, key fob is enabled to restore alerts by pressing the Unset key.
Web only Audio Expander
LED
If enabled, audio expander will not turn on LED when microphone active.
Report in Eng
mode
If enabled, the panel will always report alarm activations and panic alarms.
Outputs in Eng
Mode
If selected, the following are not deactivated in Full Engineer mode:
l
Controller outputs
l
Expander outputs
l
Indicator LEDs
l
Keyswitch LEDs
Alarm on
Reporting Fail
If a ‘Fail to Communicate‘alert is raised, external bells will activate.
Retrigger Duress If enabled, duress alarm will retrigger.
Retrigger Panic If enabled, panic alarm will retrigger.
Override Reader
Profile
If enabled, the LED behavior of readers will be controlled by the panel.
Silence Audio
Verification
If enabled, then the internal and external bells (system and area), the
keypad buzzers and annunciation messages on the Comfort Keypad will be
silenced during audio verification.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 170 I-200572