Zone attribute Description
Chime When the ‘Chime’ attribute is set for a zone, any opening of the zone during the Unset mode
will cause the internal buzzers to activate for a short period (2 seconds approx.).
The Chime attribute is valid for Alarm, Entry/Exit, and Tech. zones types.
Inhibit When the ‘Inhibit’ attribute is set, a user may inhibit this zone. The inhibit operation will disable
that fault or zone for one setting period only.
Normal Open When the ‘Normal Open’ attribute is set, the system expects that a connected detector/sensor
is a Normally Open device (for example, a sensor is deemed to be activated whenever the
contacts are closed on the device ).
Silent If the ‘Silent’ attribute is set then there will be no audio or visual indications of the Alarm. The
alarm activation will be sent to the Receiver station. If the system is unset then a warning
message is shown on the display.
Log If this attribute is set then all zone state changes are logged.
Exit Open If set then zone will be indicated if open during setting.
Frequent This attribute only applies to remote services*. If this attribute is set for a zone, the zone must
open for remote service purposes within the defined frequent time period.
End of Line The End Of Line (EOL) attribute provides a number of input zone wiring configurations on the
system.
Analysed The Analysed Attribute must be set for a zone if that zone is wired with an inertia sensor. The
Pulse count and Gross attack values should be programmed for each inertia sensor on the
system in accordance with the results of a simple calibration of the device.
Pulse Count Pulse count trigger level for analysed inertia sensors.
Gross Attack Gross attack trigger level for analysed inertia sensors
Final Exit The Final Exit attribute can only be assigned to an Entry/Exit Zone type. Use this attribute to
override the standard process of counting down the exit timer whenever the system is full set.
When all other entry/exit routes in the premises are closed, fullset the system and close the
final exit/entry zone. As soon as the door is closed the Final Exit time will count down to setting
the system.
Shunt A zone with the shunt attribute set will be inhibited whenever a shunt type zone is opened.
This provides a mechanism to group the inhibition of zones with the opening of the shunt zone
type.
Report Only This attribute only applies to the FIRE zone type. If this attribute is set, then activation of the
fire zone will only report the activation to the central station. No alarms will be generated on
site.
Open Only This attribute only applies to the KEYARM zone type. If set then the setting state of the
building will toggle on openings only.
Fullset Enable This attribute only applies to the KEYARM zone type. If this attribute is set then zone
activation will Fullset the system/area. Apply this attribute if it is intended that the user should
only have the ability to FULLSET the system from a keyarm zone.
SPC42/52/53/63 Installation & Configuration Manual Appendix
© Vanderbilt 2023 284 I-200572