216 Agilent X-Series Signal Generators User’s Guide
Basic Digital Operation (Option 653/655/656/657)
Using Finite Impulse Response (FIR) Filters in the Dual ARB Real-Time Modulation Filter
3. Use the numeric keypad to type the first value (0.000076) from Table 8- 3. As you press the
numeric keys, the numbers are displayed in the active entry area. (If you make a mistake, you can
correct it using the backspace key.)
4. Continue entering the coefficient values from the table in step 1 until all 16 values have been
entered.
Table 8-3
Coefficient Value Coefficient Value
0 0.000076 8 0.035667
1 0.001747 9 0.116753
2 0.005144 10 0.157348
3 0.004424 11 0.088484
4 0.007745 12 0.123414
5 0.029610 13 0.442748
6 0.043940 14 0.767329
7 0.025852 15 0.972149