EasyManuals Logo

Agilent Technologies X Series User Manual

Agilent Technologies X Series
426 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #95 background imageLoading...
Page #95 background image
Agilent X-Series Signal Generators User’s Guide 81
Using Analog Modulation (Option UNT)
Configuring the LF Output (Option 303)
Configuring the LF Output (Option 303)
The signal generator has a low frequency (LF) output. The LF output’s source can be switched
between an internal modulation source or an internal function generator.
Using internal modulation (Int Monitor) as the LF output source, the LF output provides a replica of
the signal from the internal source that is being used to modulate the RF output. The specific
modulation parameters for this signal are configured through the AM, FM, or ΦM menus. The internal
source (AM, FM, or ΦM) must be configured for the LF Out to provide a signal.
Using function generator as the LF output source, the function generator section of the internal
modulation source drives the LF output directly. Frequency and waveform are configured from the LF
output menu, not through the AM, FM, or ΦM menus. You can select the waveform shape from the
following choices:
Available internal waveforms include:
Sine sine wave with adjustable amplitude and frequency
Triangle triangle wave with adjustable amplitude and frequency
Square square wave with adjustable amplitude and frequency
Pos Ramp positive going ramp with adjustable amplitude and frequency
Neg Ramp negative going ramp with adjustable amplitude and frequency
Pulse pulse with adjustable period and width
LF Out Modulation Sources
The signal generator provides the following modulation input sources. Internal modulation sources
generate the five waveforms listed above unless noted otherwise.
Int Monitor uses AM, FM or ΦM settings.
Func Gen 1 waveforms from the internal function generator
Func Gen 2 waveforms from the internal function generator
Dual Func Gen dual waveforms with individually adjustable frequencies and a percent- of-
peak- amplitude setting for the second tone. Available on instruments with Option
303.
Swept Func Gen swept waveforms with adjustable start and stop frequencies, sweep time, and
sweep trigger settings. Available on instruments with Option 303.
Noise Gen 1 & 2 noise with adjustable amplitude generated as a peak- to- peak value (RMS value is
approximately 80% of the displayed value). Uniform and Gaussian distribution is
available. Available on instruements with Option 303.
DC selects a DC voltage level as the LF output BNC source
NOTE The LF Out Off On softkey controls the operating state of the LF output. However when the LF
output source selection is Int Monitor, you have three ways of controlling the output. You can
use the modulation source (AM, FM, or ΦM) on/off key, the LF output on/off key, or the Mod
On/Off softkey.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies X Series and is the answer not in the manual?

Agilent Technologies X Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelX Series
CategoryPortable Generator
LanguageEnglish

Related product manuals