EasyManua.ls Logo

Alcatel-Lucent 7750 SR - Page 460

Alcatel-Lucent 7750 SR
1948 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 460 7750 SR OS Services Guide
Only one of the pseudowires is activated based on the primary/secondary, preference
configuration and pseudowire status. In case of a tie the pseudowire located on the
master chassis will be chosen.
The rest of the pseudowires are blocked locally on the MC-EP pair and on the remote
PEs as long as they implement the pseudowire active/standby status.
Fast Detection of Peer Failure using BFD
Although the MC-EP protocol has its own keep-alive mechanisms, sharing a common mechanism
for failure detection with other protocols (for example, BGP, RSVP-TE) scales better. MC-EP can
be configured to use the centralized BFD mechanism.
Similar as other protocols, MC-EP will register with BFD if the “bfd-enable” command is active
under “config>redundancy>multi-chassis>peer>mc-ep” object. As soon as the MC-EP application
is activated using no shutdown, it tries to open a new BFD session or register automatically with
an existing one. The source-ip configuration under redundancy multi-chassis peer-ip is used to
determine the local interface while the peer-ip is used as the destination IP for the BFD session.
After MC-EP registers with an active BFD session, it will use it for fast detection of MC-EP peer
failure. If BFD registration or BFD initialization fails, the MC-EP will keep using its own keep-
alive mechanism and it will send a trap to the NMS signaling the failure to register with/open BFD
session.
In order to minimize operational mistakes and wrong peer interpretation for the loss of BFD
session, the following additional rules are enforced when the MC-EP is registering with a certain
BFD session:
Only the centralized BFD sessions using system or loopback IP interfaces (see source-ip
parameter) are accepted in order for MC-EP to minimize the false indication of peer loss.
If the BFD session associated with MC-EP protocol is using a certain interface (system/
loopback) then the following actions are not allowed under the interface: IP address
change, “shutdown”, “no bfd” commands. If one of these action is required under the
interface, the operator needs to disable BFD using the following procedures:
“no bfd-enable” command under “config>redundancy>multi-chassis>peer>mc-ep”
object – this is the recommended procedure.
shutdown from under “config>redundancy>multi-chassis>peer>mc-ep” or from
under “config>redundancy>multi-chassis>peer” objects
MC-EP keep-alives are still exchanged for the following reasons:
As a backup - if the BFD session does not come up or is disabled, the MC-EP protocol
will use its own keep-alives for failure detection.
To ensure the database is cleared if the remote MC-EP peer is shutdown or miss-
configured (each x seconds – one second suggested as default).

Table of Contents

Other manuals for Alcatel-Lucent 7750 SR

Related product manuals