EasyManua.ls Logo

Alcatel-Lucent 7750 SR - CFM Support; Mirroring; OAM Commands

Alcatel-Lucent 7750 SR
1948 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Virtual Private LAN Services
7750 SR OS Services Guide Page 815
Mirroring
There are no restrictions for mirroring in I-VPLS or B-VPLS.
OAM Commands
All VPLS OAM commands may be used in both I-VPLS and B-VPLS instances.
I-VPLS
The following OAM commands are meaningful only towards another I-VPLS service
instance (spoke-SDP in I-VPLS):
LSP-ping, LSP-trace, SDP-ping, SDP-MTU
The following I-VPLS OAM exchanges are transparently transported over the B-VPLS
core:
SVC-ping, MAC-ping, MAC-trace, MAC-populate, MAC-purge, CPE-ping (towards
customer CPE), 802.3ah EFM, SAA
PBB uplinks using MPLS/SPP: there are no PBB specific OAM commands.
B-VPLS
In case of Ethernet switching backbone (B-SAPs on B-VPLS), 802.1ag OAM is supported
on B-SAP, operating on:
The customer level (C-SA/C-DA and C-type layer)
The tunnel level (B-SA/B-DA and B-type layer)
CFM Support
There is no special 802.1ag CFM (Connectivity Fault Management) support for PBB. B-
component and I-components run their own maintenance domain and levels. CFM for I-
components run transparently over the PBB network and will appear as directly connected.