Configuring Multi-Chassis Endpoints
The following output displays configuration examples of multi-chassis redundancy and the VPLS
configuration. The configurations in the graphics depicted in Inter-Domain VPLS Resiliency
Using Multi-Chassis Endpoints on page 458 are expressed in this output.
Node Mappig to figures the document:
•PE3 = Dut-B
•PE3' = Dut-C
•PE1 = Dut-D
•PE2 = Dut-E
PE3
*A:Dut-B>config>redundancy>multi-chassis# info
----------------------------------------------
peer 3.1.1.3 create
peer-name "Dut-C"
description "mcep-basic-tests"
source-address 2.1.1.2
mc-endpoint
no shutdown
bfd-enable
system-priority 50
exit
no shutdown
exit
----------------------------------------------
*A:Dut-B>config>redundancy>multi-chassis#
*A:Dut-B>config>service>vpls# info
----------------------------------------------
fdb-table-size 20000
send-flush-on-failure
stp
shutdown
exit
endpoint "mcep-t1" create
no suppress-standby-signaling
block-on-mesh-failure
mc-endpoint 1
mc-ep-peer Dut-C
exit
exit
mesh-sdp 201:1 vc-type vlan create
exit
mesh-sdp 211:1 vc-type vlan create
exit
spoke-sdp 221:1 vc-type vlan endpoint "mcep-t1" create
stp