EasyManua.ls Logo

Alcatel-Lucent 7750 SR - Page 642

Alcatel-Lucent 7750 SR
1948 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Virtual Private LAN Services
Page 642 7750 SR OS Services Guide
This command does not require send-flush-on-failure in B-VPLS to be enabled on an IVPLS trigger
to send an MAC flush into the BVPLS.
Default no send-bvpls-flush
Parameters all-but-mine — Specifies to send an LDP flush all-but-mine and also sent into the B-VPLS. Note
that both parameters can be set together.
all-from-me — Specifies to send an LDP flush-all-from and when STP initiates a flush, it is sent into
the B-VPLS using LDP MAC flush all-from-me. Note that both parameters can be set together.
send-flush-on-bvpls-failure
Syntax [no] send-flush-on-bvpls-failure
Context config>service>vpls ivpls
Description This command enables the generation in the local I-VPLS of a LDP MAC flush-all-from-me
following a failure of SAP/the whole endpoint/spoke-SDP in the related B-VPLS. Note that the
failure of mesh-SDP in B-VPLS does not generate the I-VPLS MAC flush.
The no form of this command disables the generation of LDP MAC flush in I-VPLS on failure of
SAP/endpoint/spoke-SDP in the related B-VPLS.
Default no send-flush-on-bvpls-failure
propagate-mac-flush-from-bvpls
Syntax [no] propagate-mac-flush-from-bvpls
Context config>service>vpls ivpls
Description This command enables the propagation in the local I-VPLS of any regular LDP MAC Flush received
in the related B-VPLS. If an LDP MAC flush-all-but-mine is received in the B-VPLS context, the
command controls also whether a flush is performed for all the customer MACs in the associated I-
VPLS FIB. The command does not have any effect on a PBB MAC Flush (LDP MAC flush with PBB
TLV) received in the related B-VPLS context.
The no form of this command disables the propagation of LDP MAC Flush in I-VPLS from the
related B-VPLS.
Default no propagate-mac-flush-from-bvpls
send-flush-on-failure
Syntax [no] send-flush-on-failure
Context config>service>vpls
Description This command enables sending out “flush-all-from-ME” messages to all LDP peers included in
affected VPLS, in the event of physical port failures or “oper-down” events of individual SAPs. This