Page 834 7750 SR OS Services Guide
periodic-timer
Syntax [no] periodic-timer
Context config>service>vpls>sap>mrp
config>service>vpls>spoke-sdp>mrp
config>service>vpls>mesh-sdp>mrp
Description This command enables or disables the Periodic Transmission Timer.
Default disabled
send-flush-on-failure
Syntax [no] send-flush-on-failure
Context config>service>vpls
Description This command enables sending out “flush-all-from-ME” messages to all LDP peers included in
affected VPLS, in the event of physical port failures or “oper-down” events of individual SAPs. This
feature provides an LDP-based mechanism for recovering a physical link failure in a dual-homed
connection to a VPLS service. This method provides an alternative to RSTP solutions where dual
homing redundancy and recovery, in the case of link failure, is resolved by RSTP running between a
PE router and CE devices. If the endpoint is configured within the VPLS and send-flush-on-failure is
enabled, flush-all-from-me messages will be sent out only when all spoke SDPs associated with the
endpoint go down.
This feature cannot be enabled on management VPLS.
Default no send-flush-on-failure
pbb
Syntax pbb
Context config>service
config>service>vpl
config>service>epipe
Description This command configures global PBB parameters.
mac-name
Syntax mac-name name ieee-address
no mac-name name
Context config>service>pbb