GreenDrill control terminal 5.2
86
GreenDrill BAH0054-9 11.17
Error message Description Remedy
The calibration distance
is too short
"pulses/100 m"
Repeat the calibration,
(see section 7.7, page 75)
The seeding shaft speed is too
low.
Display
during seed calibration
Use seed metering wheels with
a smaller volume
or
seeding shaft with fewer seed
metering wheels
Seeding shaft speed is too high
Display
during seed calibration
Use seed metering wheels with
a larger volume
or
seeding shaft with more seed
metering wheels
Calibration time is too short
Display
when using the calibration but-
ton
Press and hold the
calibration button for
at least 30 seconds
during calibration
Forward speed too high
Compare the displayed
speed with the actual driv-
en speed
Reduce the forward
speed or
Use larger seed metering
wheels
The forward speed is too low
Compare the displayed
speed with the actual driv-
en speed
Increase the forward
speed or
Use smaller seed metering
wheels