GreenDrill control terminal 5.2
90
GreenDrill BAH0054-9 11.17
Continuous or occasional for-
ward speed display: 0.0 km/h
The speed signal is not being detected
Set the signal in section 7.20.4 to NO, if all of the settings in the
sections
section 7.20.4, section 7.20.5, section 7.20.6, section 0 and section
0
(
from page 100) are set to AUTO.
The spread rate (kg/ha or
grains/m
2
) is not displayed
Calibrate the seed
(see section 7.6, page 69)
The GreenDrill is spreading
too much or too little seed
Correct the speed
Calibrate the speed sensor
(see section 7.7,
page 75).
Not required with GPS device.
Check the hectare counter
(see section 7.8,
page 79)
Calibrate the seed
(see section 7.6,
page 69)
Lifting unit sensor not correctly set
switches over during operation
Only hydr. blower fan:
Reduce the blower fan speed
The pressure in the oil return
flow may is greater than
10 bar
Check the return line of the hydraulic hose line on the tractor
(see section "Connecting the hydraulic hose lines to the
tractor", page 47)
Use a larger return flow line
Use a larger hydraulic coupling
Use a new return line filter