CPS100 SERIES OPERATION MANUAL
SECTION 7:
Remote Control Programming
Entire Contents Copyright 2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual Page 167 of 231
7.8.4 STEP Sub-system
The STEP sub-system controls output transient step mode programming.
Command
Description
STEP:COUNT:_<nr2>
Sets the number of steps. Range is 0 ~ 9999. A 0 value means
infinite loop. Returns OK or FALSE.
STEP:DEGREE:_<nr2>
Sets the start angle of the steps in degrees. Range is 0.0 ~
359.9. Returns OK or FALSE.
STEP:DFREQ:_<nr2>
Sets the step value of the Frequency in Hz. Range is 15.00 ~
1000.00 for Standard models or 15.00 ~ 1200.00 for Enhanced
models. Returns OK or FALSE.
STEP:DVAC:_<nr2>
Sets the step increment value for the AC voltage in volts. Range
is -300.0 ~ 300.0. Returns OK or FALSE.
STEP:DVDC:_<nr2>
Sets the step increment value for the AC voltage in volts. Range
is -424.2 ~ 424.2. Returns OK or FALSE.
STEP:DWELL:_<nr2>
Sets the duration of each step in msec. Range is 0 ~ 9999999.9.
Returns OK or FALSE.
STEP:FREQ:_<nr2>
Sets the starting frequency in Hz. Range is 15.00 ~ 1000.00 for
Standard models or 15.00 ~ 1200.00 for Enhanced models.
Returns OK or FALSE.
STEP:MAXPOWER:FREQ?
Queries the frequency reached at the maximum power point in
Hz.
STEP:MAXPOWER:I?
Queries the current reached at the maximum power point in
amps.
STEP:MAXPOWER:P?
Queries the power reached at the maximum power point in
Watts.
STEP:MAXPOWER:PF?
Queries the power factor reached at the maximum power
point.
STEP:MAXPOWER:V?
Queries the voltage reached at the maximum power point in
volts.
STEP:PAUSE
Pauses or resumes the step transient. Returns OK.
STEP:POWERSWEEP:_<nr2>
Enables (1) or Disables the power sweep function.
STEP:REMAINTIME?
Queries the remaining time left for the step transient in secs.
STEP:TRIGER
>>> STEP:TRIGGER <<<
Starts execution of the step transient. Returns OK.
Note: Remote firmware revision V100R002C21 of lower will not accept
correct spelling of TRIGGER key word. Use TRIGER as shown instead.
STEP:STOP
Abort execution of the step transient. Returns OK.
STEP:VAC_<nr2>
Sets the start AC voltage in volts. Range is 0.0 ~ 300.0. Returns
OK or FALSE.
STEP:VDC_<nr2>
Sets the start DC voltage in volts. Range is -424.2 ~ 424.2.
Returns OK or FALSE.
STEP:WAVEFROM:_<nr2>
Selects waveform group A (0) or B (1) for the step. Returns OK
or FALSE.
Table 7-12: STEP Sub-system Commands