EasyManua.ls Logo

APS CPS100 Series - Table 13-1: Troubleshooting Matrix

APS CPS100 Series
231 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CPS100 SERIES OPERATION MANUAL
SECTION 13:
Error Messages & Troubleshooting
Entire Contents Copyright 2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual Page 227 of 231 PN 160953-10
Problem
Possible Causes
Possible Solutions
Screen shows message
C014 SHORT ALARM
Output wiring short
circuit or connected load
shorted
Turn off the output and check the output
cables to make sure they are connected
correctly before turning power back on.
Screen shows message
C015 RCP ALARM
RCP circuit failed Contact customer service
Screen shows message
C016 OUTPUT 1 OVP
Remote voltage sense
compensation exceeds
5V
Make sure remote voltage sense
compensation is no more than 5 volts.
Screen shows message
SELF TEST FAIL
Power on self-test failed Contact customer service
Screen shows message
UNACTIVATED
Activation Failure Contact customer service
Table 13-1: Troubleshooting Matrix

Table of Contents