CPS100 SERIES OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright 2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual Page 36 of 231
Environmental
Operating Environment
Temperature Operating
0° to 40° C / 32° to 104° F
Storage
-40° to 85° C / -40° to 185° F
Fan Cooled
Temperature controlled. Front intake rear exhaust.
Fan noise 73 dBA at max. fan speed
Temperature Coefficient
Voltage: 100ppm/°C, Current: 300ppm/°C, Frequency: 100ppm/°C
Rel. Humidity
5% to 95% non-condensing
Altitude Operating
2000 m / 6560 feet
Safety & Regulatory
REGULATORY COMPLIANCE
Emissions
CE marked per EMC Directive 2014/30/EU/EN61326-1:2013 Class A
for emissions and immunity as required
for CE Mark. FCC verification
for conformity for CFR 74 Part 15 of FCC rules
Safety
CE marked per LVD Directive 2014/35/EU/EN61010-1, third edition
as required for CE Mark
CE Mark
Installation Over voltage Category II, Pollution Degree 2, Class II
Equipment, indoor use only
UL Listing
CSA NRTL certified for US and Canada to CAN/CSA-22.2 No. 61010-1-
12, UL 61010-1 Third Edition
Isolation Voltage
3000Vac Input to Output, 1500Vac Input to Chassis
RoHS
Meets EU Directive 2011/65/EU for restriction of hazardous
substances in Electrical and Electronic Equipment
Refer to Declaration of Conformity sheet in Section 14, “CE MARK Declaration of Conformity” at
the end of this manual.