EasyManua.ls Logo

APS CPS100 Series - Programming Commands; OUTPUT Sub-System

APS CPS100 Series
231 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CPS100 SERIES OPERATION MANUAL
SECTION 7:
Remote Control Programming
Entire Contents Copyright 2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual Page 156 of 231
Programming Commands
The following command and queries are available to program the output of the power
source.
Note: These measurement commands apply to an individual CPS100 series power source.
For Master/Slave configuration measurement commands, refer also to Section
7.2.1, “Master / Slave Programming Commands” on page 171.
7.8.1 OUTPUT Sub-system
The OUTPUT sub-system commands control output related parameters and configurations.
Command Description
OUTPUT:VAC:_<nr2> Sets the AC output voltage in volts. Setting range is 0.0 ~
300.0. Returns OK or FALSE.
OUTPUT:VAC? Queries AC output voltage setting.
OUTPUT:VDC:_<nr2> Sets the DC output voltage in volts. Setting range is 424.4
~ 424.2. Returns OK or FALSE.
OUTPUT:VDC? Queries DC output voltage setting.
OUTPUT:FREQ:_<nr2> Sets the output frequency in Hz. Range is 15.00 ~ 1000.00
on Standard version models or 15.00 ~ 1200.00 on
Enhanced version models. Returns OK or FALSE.
OUTPUT:FREQ? Queries the output frequency setting
OUTPUT:RELAY:_<nr2> Turns the output on (ON) or off (OFF) by closing or
opening the output relay. Returns OK or FALSE.
OUTPUT:RELAY? Queries the output relay state.
0 = Open or OFF , 1 = Closed or on
OUTPUT:OUT:<STATE> Enables the output to be (STATE = ON) or disables the
output (STATE = OFF). Returns OK or FALSE.
OUTPUT:OUT? Queries the output state. Returns ON or OFF
OUTPUT:WAVEFORM:SELECT:_<nr2> Sets the output waveform to group A (0) or B (1). Returns
OK or FALSE.
OUTPUT:WAVEFORMA:_<nr2>,<nr3> Sets the parameters of waveform A. Returns OK or FALSE.
<nr2> 0 SINE
1 SIQUA
2 CSINE <nr3> 0 ~ 100
3 FIXED 0 ~ 29
4 USER 0 ~ 5

Table of Contents