Version 6.6 409 MP-11x & MP-124
User's Manual 41. Testing SIP Signaling Calls
Parameter Description
Authentication Tab
Note: These parameters are applicable only if the test endpoint is set to Caller (see the 'Call Party'
parameter).
Auto Register
[Test_Call_AutoRe
gister]
Enables automatic registration of the endpoint. The endpoint can register to
the device itself or to the 'Destination Address' or 'IP Group ID' parameter
settings (see above).
[0] False (default)
[1] True
User Name
[Test_Call_UserNa
me]
Defines the authentication username.
By default, no username is defined.
Password
[Test_Call_Passwo
rd]
Defines the authentication password.
By default, no password is defined.
Test Settings Tab
Call Party
[Test_Call_CallPart
y]
Defines whether the test endpoint is the initiator or receiving side of the test
call.
[0] Caller (default)
[1] Called
Maximum Channels
for Session
[Test_Call_MaxCha
nnels]
Defines the maximum number of concurrent channels for the test session.
For example, if you have configured an endpoint "101" and you set this
parameter to "3", the device automatically creates three simulated endpoints
- "101", "102" and "103" (i.e., consecutive endpoint URIs are assigned).
The default is 1.
Call Duration
[Test_Call_CallDur
ation]
Defines the call duration (in seconds).
The valid value is -1 to 100000. The default is 20. A value of 0 means
infinite. A value of -1 means that the parameter value is automatically
calculated according to the values of the 'Calls per Second' and 'Maximum
Channels for Session' parameters.
Note: This parameter is applicable only if 'Call Party' is set to Caller.
Calls per Second
[Test_Call_CallsPer
Second]
Defines the number of calls per second.
Note: This parameter is applicable only if 'Call Party' is set to Caller.
Test Mode
[Test_Call_TestMo
de]
Defines the test session mode.
[0] Once = (Default) The test runs until the lowest value between the
following is reached:
Maximum channels is reached for the test session, configured by
'Maximum Channels for Session'.
Call duration ('Call Duration') multiplied by calls per second ('Calls
per Second').
Test duration expires, configured by 'Test Duration'.
[1] Continuous = The test runs until the configured test duration is
reached. If it reaches the maximum channels configured for the test
session (in the 'Maximum Channels for Session'), it waits until the
configured call duration of a currently established tested call expires
before making the next test call. In this way, the test session stays within
the configured maximum channels.
Note: This parameter is applicable only if 'Call Party' is set to Caller.

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet