Cable lengths and resolutions for SDL transfer
The following table shows the relationship between segment lengths and the maximum
resolution according to the SDL cable used:
The cable types and resolutions shown with a footnote 1) in the previous table can only be
implemented starting with the following firmware and hardware versions:
Cables
Segment length [m]
Resolution
XGA
1024 x 768
1.8 5CASDL.0018-20
5 5CASDL.0050-20
10 5CASDL.0100-20
15 5CASDL.0150-20
20 5CASDL.0200-20
1)
1) See table 133 "Requirements for SDL cable with automatic cable adjustment (equalizer)"
25 5CASDL.0250-20
1)
30 5CASDL.0300-30
2)
2) See table 134 "Requirements for SDL cable with extender and automatic cable adjustment (equalizer)"
40 5CASDL.0400-30
2)
Table 132: Segment lengths, resolutions and SDL cables
Firmware Name Version Note
MTCX FPGA Firmware on the APC620 v 01.15 The version is read from BIOS - see the BIOS
description.
Supported starting with the APC620 / PPC 700
Firmware upgrade (MTCX, SDLR, SDLT) V01.10,
available in the download area of the B&R
homepage.
MTCX PX32 Firmware on the APC620 v 01.55
Table 133: Requirements for SDL cable with automatic cable adjustment (equalizer)