R5906848 /04 DP2K SLP Series324
Code 5641: light source - light is on, but SMPS is off (Error)
Situation Solution
This error alone, or with other
SMPS errors: Malfunction
SMPS module
Replace the SMPS module. See Switch Mode Power Supply (SMPS),
page 39.
This error alone: Defect Signal
Backplane
Replace the Signal Backplane. See Card Cage, page 209.
In combination with other
errors
Check the projector log files for other listed errors and solve these errors
first.
Code 5646: light source - Switching on the light source failed (Error)
Situation Solution
The light source goes out
immediately after powering it,
or does not go on at all.
Check the projector log files for other listed errors and solve these errors
first.
Code 5647: light source - The light source was switched off due to an error (Error)
Situation Solution
The light source was triggered
to switch off the lasers due to
an error.
Check the projector log files for other listed errors and solve these errors
first.
Code 5800: TI-boards - system status = fail
This is a generic TI error. Use the Communicator to make a detailed analysis. Go to Diagnostics > Actual >
Cinema Front End Status > Detailed status > Error Messages. Possible error messages are:
Situation Solution
Malfunction software. Reboot the projector.
ICP board is not correctly
seated.
Reseat the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
ICP self test - ICP frame
memory test failed
Replace the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
ICP self test - ICP data path
signature test failed
Check the connections to the Formatter boards on the Light Processor.
Replace the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
ICP Normal Configuration
Error
Replace the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
ICP Boot Configuration Error Replace the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
FMT Normal Configuration
Error
Replace the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
FMT Boot Configuration Error Replace the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
FMT Satellite Configuration
Error
Replace the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
1.20V Supply out of range Replace the ICP board. See service manual chapter Replacement of the
ICP board, page 214.
Troubleshooting

Table of Contents

Other manuals for Barco DP2K SLP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco DP2K SLP Series and is the answer not in the manual?

Barco DP2K SLP Series Specifications

General IconGeneral
BrandBarco
ModelDP2K SLP Series
CategoryProjector
LanguageEnglish

Related product manuals