Error information
Manual b maXX
®
BM1000
Document No. 5.07003.04 Baumüller Nürnberg GmbH
86
of 174
8.3
0515
hex
cF30 U-phase error PWM
inhibit
m Return to the factory
0516
hex
cF31 V-phase error PWM
inhibit
0517
hex
cF32 W-phase error PWM
inhibit
0518
hex
ocA Overcurrent during
acceleration
PWM
inhibit
m Short-circuit at motor output: Check for
possible poor insulation at the output
lines.
m Torque boost too high: Decrease the
torque compensation setting in P0112.
m Acceleration time too short: Increase the
acceleration time.
m Device output power is too small: Re-
place the device with the next higher
power model.
0519
hex
ocd Overcurrent during
deceleration
PWM
inhibit
m Short-circuit at motor output: Check for
possible poor insulation at the output line.
m Deceleration time too short: Increase the
deceleration time.
m Device output power is too small: Re-
place the device with the next higher
power model.
Fault
code
Fault
name
Fault description Error
reaction
Corrective actions