9.3.3 Part On, Instant
Default:P
Selections: - , E, P
– Disable (-) - Disable this function panel wide regardless of the user's authority level.
– Enable (E) - Enable this function panel wide without requiring a passcode.
– Passcode (P) - Require a passcode to enable this function panel wide.
This function turns areas part on with no entry/exit delays in the area where the keypad is
assigned. This causes perimeter and interior delay points to act as instant points.
Notice!
To comply with SIA CP-01 False Alarm Reduction, set this parameter to Disabled (-). Refer to
SIA CP-01 Verification for more information.
RPS Menu Location
User Configuration > User Keypad Functions > Part On Instant.
9.3.4 Part On, Delay
Default:P
Selections: - , E, P
– Disable (-) - Disable this function panel wide regardless of the user's authority level.
– Enable (E) - Enable this function panel wide without requiring a passcode.
– Passcode (P) - Require a passcode to enable this function panel wide.
This function turns areas part on with entry/exit delays in the area where the keypad is
assigned.
Entry and exit delays are provided with this arming function. This will not cause a Part On
instant point to act as a delay point.
RPS Menu Location
User Configuration > User Keypad Functions > Part On Delay.
9.3.5 Watch Mode
Default:E
Selections: - , E, P
– Disable (-) - Disable this function panel wide regardless of the user's authority level.
– Enable (E) - Enable this function panel wide without requiring a passcode.
– Passcode (P) - Require a passcode to enable this function panel wide.
This function turns watch mode on and off.
This function provides keypad audible/visual and optional output activation when a point
configured for Watch Mode is activated. (Refer to Watch Mode in the Area Wide Outputs
section).
RPS Menu Location
User Configuration > User Keypad Functions > Watch Mode
9.3.6 View Area Status
Default:P
Selections: - , E, P
– Disable (-) - Disable this function panel wide regardless of the user's authority level.
– Enable (E) - Enable this function panel wide without requiring a passcode.
– Passcode (P) - Require a passcode to enable this function panel wide.
This function allows the user to view the armed status of all areas within the scope of the