EasyManua.ls Logo

Bosch B9512G - User Change Reports; Access Reports

Bosch B9512G
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control Panel Panel Wide Parameters | en 57
Bosch Security Systems, Inc. Program Entry Guide 2017.03 | 09 | F.01U.303.998
Point Reports
Route Group 1 Route Group 2 Route Group 3 Route Group 4
Send Point Text Yes Yes Yes No
RF Low Battery Yes Yes Yes No
RF Low Battery Restore Yes Yes Yes No
Bypass Yes Yes Yes No
Bypass Restore Yes Yes Yes No
Selections:
– Yes - assign this report to the Route Group.
– No - do not assign this report to the Route Group.
RPS Menu Location
Panel Wide Parameters > Report Routing > Point Reports.
RPS Menu Location
Panel Wide Parameters > Report Routing > Point Reports
3.9.12 User Change Reports
Default:
User Change Reports
Route Group 1 Route Group 2 Route Group 3 Route Group 4
Date Changed Yes Yes Yes Yes
Time Changed Yes Yes Yes No
Delete User Yes Yes Yes No
User Code Change Yes Yes Yes No
Area Watch Yes Yes Yes No
Keyfob Assigned Yes Yes Yes No
Keyfob Removed Yes Yes Yes No
Change Level Yes Yes Yes Yes
Selections:
– Yes - assign this report to the Route Group.
– No - do not assign this report to the Route Group.
RPS Menu Location
Panel Wide Parameters > Report Routing > User Change Reports.
3.9.13 Access Reports
Default:
Access Reports
Route Group 1 Route Group 2 Route Group 3 Route Group 4
Access Granted Yes Yes Yes Yes
No Entry Yes Yes Yes Yes
Door Left Open Yes Yes Yes Yes

Table of Contents