172 en | User Configuration Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
Allow a user with this authority level to arm an area by entering their passcode, then pressing
the [ENTER] key.
Authority Level 15 is reserved for the Service Passcode (User 0) and cannot be changed.
RPS Menu Location
User Configuration > Authority Levels > Arm by Passcode
9.4.44 Disarm by Passcode
Default:
Authority Levels 1-5, 14: Enabled (E)
Authority Levels 6-13, 15: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
Allow a user with this authority level to disarm an area by entering their passcode, then
pressing the [ENTER] key.
Authority Level 15 is reserved for the Service Passcode (User 0) and cannot be changed.
Configure the Duress Enable parameter to Yes in applicable areas, or the keypad will respond
with No Authority.
Duress Disarm Profile
User Authority Level 14 is programmed by default as a Duress disarm profile. When Duress
Type is set to 3, the SIA CP-01 compliant Duress Passcode feature is enabled. Duress Types 1
and 2 are not allowed in SIA CP-01 compliant installations.
With Authority Level 14 assigned to a user passcode in an area, that user has the authority to
disarm and send a Duress event from that area.
All Duress-capable passcodes must be unique and cannot be derived from other passcodes.
To facilitate this uniqueness, User Authority Level 14 is pre-programmed from the factory as
an example of Duress Disarm authority.
A Duress Disarm user authority level requires the following functions to be enabled:
– Disarm Select, page 158
– Send Duress, page 171
– Disarm by Passcode, page 172
RPS Menu Location
User Configuration > Authority Levels > Disarm by Passcode
9.4.45 Security Level
Default:
Authority Levels 1, 2: All On (A)
Authority Levels 3-5: Part On (P)
Authority Level 6: Disarmed (D)
Authority Levels 7-15: No Access (-)
Selections:
– All On (A):Users have access rights for this area when the area in any armed state.
– Part On (P):Users have access rights for this area when the area is Part On or disarmed,
but not when the area is all on Armed.
– Disarmed (D):Users have access rights for this area only when it is disarmed.
– No Access (-):Users do not have access rights to this area.
When the user presents a token/card at the reader, access is granted only when the user has
the authority to enter the area under certain armed conditions.