EasyManua.ls Logo

Bosch B9512G - Send Test on off Normal; Go to Area; Watch on; Watch off

Bosch B9512G
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
224 en | Schedules Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
11.5.29 Send Test on Off Normal
In order to generate this event, one or more points must be in an off-normal state at the time
the Sked executes. Expanded Off-Normal Test Reports include the Off Normal Test Report
event as well as events for any points that are in an off-normal state at the time the report is
generated.
This function sends the following report to the central station if the point is in an off-normal
state:
Modem event Contact ID event Contact ID code
Test Report – System off-
normal, expanded status
Periodic Test – System
Trouble Present
1 608 00 000
Non-Expanded Off-Normal Test Report events are only sent when any point is in the off-normal
state from any area but only sends the Off Normal Test Report event.
11.5.30 Go to Area
This function emulates the Go To Area keypad shortcut and is only available to custom
functions activated through a keypad. When activated, this function will change the keypads
current area to the one programmed in Parameter 1: Area #.
11.5.31 Watch On
This function emulates the operation of the keypad shortcut Change Watch Mode by activating
Match mode for the areas programmed in Parameter 1: Area #. Watch mode causes a chime at
any keypad within scope when a watch point is faulted while disarmed.
11.5.32 Watch Off
This function emulates the operation of the keypad shortcut Change Watch Mode by
deactivating Match mode for the areas programmed in Parameter 1: Area #.
11.5.33 Show Date & Time
This function emulates the keypad shortcut Show Date & Time by displaying the current time
and date at the SDI2 keypads specified in Parameter 1: Keypads #.
Notice!
When using the Show Date & Time function with the Set Keypad Volume or Set Keypad
Brightness functions in the same custom function they must be separated by about 10
seconds with the Delay function.
11.5.34 Sound Watch Tone
This function is not available as a keypad shortcut. When activated, this function causes the
SDI2 keypads specified in Parameter 1: Keypads # to continuously emit a watch beep until
silenced.
11.5.35 Set Keypad Volume
This function sets the configured keypads shown in Parameter 1: Keypad # to the volume level
entered in Parameter 2: Volume Level. Refer to Keypad Volume, page 119 in the keypad
configuration section for details on volume parameters.