Control Panel Hardware switch settings | en 263
Bosch Security Systems, Inc. Program Entry Guide 2017.03 | 09 | F.01U.303.998
15.7 B520 Power Supply switch settings
The rotary address switch range for the B520 Power Supply is between 1 and 8 for the
B9512G and between 1 and 4 for the B8512G control panels. Address ranges 00 and 05-99
are not valid on the SDI2 device bus. The factory default setting is 01. When using more than
one power supply, assign each power supply a different switch setting.
Valid B520 switch settings
01
02
03
04
05
06
07
08
15.8 B810 RADION wireless receiver switch settings
B810 and B820 address switches provide a single-digit setting for the module’s address. The
module uses address 1. Addresses 0 and 2 through 9 are invalid.
15.9 B820 Inovonics wireless receiver switch settings
The B820 Inovonics address switches provide a single-digit setting for the module’s address.
The module uses addresses 1 through 4. Addresses 0 and 5 through 9 are invalid.
Only address 1 is valid for these control panels.
15.10 B901 Access Module switch settings
Two address switches determine the address for the B901 Access Control Module. The
control panel uses the address for communications.
Use a slotted screwdriver to set the address switches.
Address Designation
0,0 Disabled
0,1 to 3,2 Doors 1 to 32 on SDI2 (SDIx in SDI2 mode),
Doors 1 to 8 for B8512
8,1 to 8,8 Doors 1 through 8 on SDIx bus in Legacy SDI
mode (D9210C with Fail Safe Unlock)
9,1 to 9,8 Doors 1 through 8 on SDIx bus in Legacy SDI
mode (D9210C with Fail Safe Lock)