238 en | SDI2 modules Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
14 SDI2 modules
14.1 B208 Octo-input
The B208 Octo-input is a device that attaches to the SDI2 bus of the control panel. Each
module provides 8 independently monitored control loops.
Panel type Modules supported
B9512G 59
B8512G 9
Tab.14.1: Capacity
Settings
RPS supports the configuration of the Enclosure Tamper, page 238 on each of the Octo-input
modules.
Yes = Enable enclosure tamper
No = Disable enclosure tamper. The default setting is No.
Switch Settings
Refer to Hardware Switch Settings > B208 Octo-input Module switch settings, page 258
14.1.1 Enclosure Tamper
Default: No - Disable
Selections:
Yes - Enable enclosure tamper input
No - Disable enclosure tamper input
This parameter enables the enclosure tamper switch input on the SDI2 module.
When the input is enabled and connected to a Bosch ICP-EZTS tamper switch installed in the
module enclosure, the control panel can create a tamper event when the enclosure door is
opened, or when the enclosure is removed from the wall.
RPS Menu Location
SDI2 modules > B208 Octo-input > Enclosure Tamper
14.2 B299 POPEX
Attach the B299 POPEX device to the SDI2 bus of the control panel.
Panel type Modules supported
B9512G 6
B8512G 1
Tab.14.2: Capacity
Settings
RPS supports the configuration of the Enclosure Tamper, page 238 on each of the POPEX
modules.
Yes = Enable enclosure tamper.
No = Disable enclosure tamper. The default setting is No.
Switch Settings
Refer to Hardware Switch Settings > B299 POPEX Module switch settings, page 260