168 en | User Configuration Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
This parameter allows the user with this authority level to reset sensors.
Notice!
To comply with UL 864 requirements for Commercial Fire Systems, program this parameter
with a relay.
Authority level 15 is reserved for the Service Passcode (User 0) and cannot be changed.
RPS Menu Location
User Configuration > Authority Levels > Reset Sensors
9.4.32 Change Output(s)
Default:
Authority Levels 1, 2, 15: Enabled (E)
Authority Levels 3-14: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
This parameter allows the user with this authority level to set OUTPUT ON and reset OUTPUT
OFF outputs in the control panel.
Do not use the CHANGE OUTPUTS function to toggle outputs reserved for special functions.
Special function outputs are Area and Panel Wide output functions as well as outputs assigned
to Enter Key Output, page 113.
Authority Level 15 is reserved for the Service Passcode (User 0) and cannot be changed.
RPS Menu Location
User Configuration > Authority Levels > Change Outputs
9.4.33 Remote Program
Default:
Authority Levels 1-4, 15: Enabled (E)
Authority Levels 5-14: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
This parameter allows the user with this authority level to initiate an RPS session when the
phone rings at the control panel.
Authority Level 15 is reserved for the Service Passcode (User 0) and cannot be changed.
RPS Menu Location
User Configuration > Authority Levels > Remote Programming
9.4.34 Go to Area
Default:
Authority Levels 1, 2, 15: Enabled (E)
Authority Levels 3-14: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.