202 en | Points Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
– 24-Hour, page 203
– Part On, page 203
– Interior, page 204
– Interior Follower, page 204
Use this feature to delay the effect of the following parameters:
– Point Response, page 184
– Instant Alarm
– Supervisory
– Output Response Type, page 194
– Display as Device, page 194
– Output, page 179
Notice!
Point Response (D) Delay Alarm is not supported by Delay Response feature. So, when a
Delay Alarm results in an instant alarm, that alarm is not delayed by this feature.
RPS Menu Location
Points > Point Indexes (point profiles) > Delay Response Armed
10.3.34 Circuit Style
Default: Single EOL (1KΩ)
Selections:
– Single EOL (1KΩ)
– Single EOL (2KΩ)
– Dual EOL
– No EOL
This parameter sets the circuit style for a point index.
Notice!
Circuit Style control panel firmware requirements
The Circuit Style Parameter is not available for control panel firmware v2.xx.
The Dual EOL resistor configuration is available only for control panel firmwarev3.01 and
higher.
The Single EOK (2KΩ) selection is only for control panel firmware v3.03 and higher.
The No EOL selection is only for control panel firmware v3.03 and higher.
Single EOL (1KΩ) – valid with all point sources.
Single EOL (2KΩ), Dual EOL, No EOL – valid with On-board and B208 point sources.
RPS Menu Location
Points > Point Indexes (point profiles) > Point Type/Response/Circuit Style
Further information
Point Type, page 184
Point Response, page 184
10.3.35 Normal State
(Not available on version 2.xx control panels.)
Default: Open
Selections:
– Open – an open point circuit is the Normal state.
– Short – a short on point circuit is the Normal state.