74 en | Panel Wide Parameters Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
The control panel dials the programmed number using RPS Phone # as a result of the
following events:
– Log % Full, page 71 threshold is achieved (if enabled).
– The control panel is contacted by RPS and RPS Call Back, page 72 is programmed Yes.
– User selects MENU > Actions > RPS > Call Via Phone (only one attempt is made).
If this parameter is left empty (blank), the control panel does not dial a phone number for
RPS. Refer to Phone Destination 1 (to 4), page 28 when programming this parameter.
RPS Menu Location
Panel Wide Parameters > RPS Parameters > RPS Phone
3.14.9 RPS Modem Speed
Default: 1200
Selections:
– 300
– 1200
– 2400
This parameter sets the baud rate for RPS-to-control panel-communication when using a PSTN
connection.
RPS Menu Location
Panel Wide Parameters > RPS Parameters > RPS Modem Speed.
3.15 Miscellaneous
3.15.1 Duress Type
Default:0
Selections:
– 0 - disabled.
– 1 - increase the last digit by 1 to generate an alarm. For example:
– If the passcode is 6123, 6124 activates a duress alarm.
– If the last digit of the passcode is 0, a duress alarm occurs when the user enters 1 as
the last digit of the passcode.
– If the last digit of the passcode is 9, a duress alarm occurs when the user enters 0 as
the last digit of the passcode.
– 2 -increase the last digit by 2 to generate an alarm. For example:
– If the last digit of the passcode is 8, a duress alarm occurs when the user enters 0 as
the last digit of the passcode.
– If the last digit of the passcode is 9, a duress alarm occurs when the user enters 1 as
the last digit of the passcode.
– 3 -send a Duress event when any user passcode entered with Send Duress, page 171 set
to Yes.
This parameter determines whether users add one (+1) or two (+2) to the last digit of the
passcode. To activate a duress alarm, the user increases the value of the last digit of their
passcode when entering it at the keypad.
Notice!
SIA CP-01 False Alarm Reduction requirement
To comply with SIA CP-01 False Alarm Reduction, set this parameter to 3. Refer to SIA CP-01
Verification for more information
Duress is enabled or disabled by area in Area Parameters, Duress Enable, page 96.