Control Panel Points | en 201
Bosch Security Systems, Inc. Program Entry Guide 2017.03 | 09 | F.01U.303.998
Use this parameter to configure the length of time (MM:SS) a disarmed control panel waits
after a point faults before reporting the event to the central station.
The control panel sends a Burg Supervisory report to the central station if the point remains
faulted during the entire period of time configured in this parameter. If the point is restored
during this time, no report is sent. The control panel does not indicate monitor delay at the
keypad.
Enable this feature to monitor a door, such as a trash compactor, jewelry case, or freezer that
should not be left open.
Notice!
Starting a walk test that includes controlled points, or arming the points' area will cancel the
monitor point timer. No report is sent after the configured time expires.
RPS Menu Location
Points > Point Indexes (point profiles) > Monitor Delay
10.3.32 Delay Response, Disarmed
Default: 00:00
Selections: 00:05 thru 60:00
00:00 = disabled
This parameter sets the length of time (MM:SS) the control panel waits after a disarmed point
faults before annunciating or reporting the fault. This parameter only applies to the following
point types when armed:
– Part On, page 203
– Interior, page 204
– Interior Follower, page 204
Use this feature to delay the effect of the following parameters:
– Point Response, page 184
– Instant Alarm
– Supervisory
– Buzz on Fault, page 193
– Watch Point, page 193
– Output Response Type, page 194
– Display as Device, page 194
– Output, page 179
Notice!
Point Response (D) Delay Alarm is not supported by Delay Response feature. So, when a
Delay Alarm results in an instant alarm, that alarm is not delayed by this feature.
RPS Menu Location
Points > Point Indexes (point profiles) > Delay Response Disarmed
10.3.33 Delay Response, Armed
Default: 00:00
Selections: 00:05 thru 60:00
00:00 = disabled
This parameter sets the length of time (MM:SS) the control panel waits after an armed point
faults before annunciating or reporting the fault. This parameter only applies to the following
point types when armed: