208 en | Schedules Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
Programming for two Opening Windows on the same day (as shown in the time line)
Open Close
W# Day of
the week
Early
begin
Start Stop Early
begin
Start Stop Except
on
Holiday
1 SMTWT
FS
06:00 07:00 08:00 23:59 Yes / No
2 SMTWT
FS
13:00 14:00 15:00 01:00 Yes / No
Do not program a single window to cross the midnight boundary. The window stop time must
be later than the window start time. To program a window that effectively crosses the
midnight boundary, you have to program two windows.
For example, to program windows for an area that opens between 11:30 PM and 12:30 AM,
five days a week, use two windows as shown in the example below:
Programming to Link Two Days Over Midnight
Open Close
W# Early
begin
Start Stop Early
begin
Start Stop Except
on
Holiday
Holiday
index
Area(s)
1 /
Monday
22:00 23:30 23:59 Yes /
No
1234 123456
78
2 /
Monday
00:00 00:00 00:30 Yes /
No
1234 123456
78
11.1.2 Opening_Closing windows table
Monday to Friday, opening between 5 and 6 AM, closing between 11 PM and 1 AM.
Open Close
W# Day of
the week
Early
begin
Start Stop Early
begin
Start Stop Except
on
Holiday
1 SMTWT
FS
04:00 05:00 06:00 20:00 23:00 23:59 Yes / No
2 SMTWT
FS
00:00 00:00 01:00 Yes / No
Sunday, in between 8 and 8:30 AM, out between 2:30 and 5:00 PM.
Open
W# Day of week Early begin Start Stop
4 SMTWTFS 07:00 08:00 08:30
All days must be
programmed NO
Only on holidays

Table of Contents