Control Panel Points | en 181
Bosch Security Systems, Inc. Program Entry Guide 2017.03 | 09 | F.01U.303.998
Device type Input 1 Input 2 Input 3 Input 4
Motion dual Motion alarm Not used Not used Not used
Motion PIR PIR alarm Not used Not used Not used
Ceiling mount
motion
Motion alarm Not used Not used Not used
Universal TX Reed alarm Loop input Not used Not used
Bill trap Bill trap alarm Not used Not used Not used
Curtain motion PIR alarm Not used Not used Not used
CO detector CO alarm Not used Not used Not used
Panic, one
button
Not used Not used Not used Not used
Panic, two
button
Not used Not used Not used Not used
Each point device must have at least one valid input function selected.
RPS will reset this field to the default value when the wireless device type is changed.
NOTE: To expand or collapse the list of Point numbers, use the arrows at the top of the RPS
screen.
RPS Menu Location
Points > Point Assignments > RADION Device Type
10.1.11 Inovonics RFID (B820)
Default: N/A
Selections: 0 - 167772156
A point RFID can be Auto-Learned through the SDI2 bus RF receiver, or it can be entered here.
Auto-Learned RFIDs can be edited for point replacement, or can be set to 0 to disable a RF
point. An RFID (Radio Frequency device Identification number) is a unique number assigned to
a wireless device at the factory. It provides a unique way for the Wireless Receiver and
Wireless Repeaters to identify what device is transmitting.
If the configuration option, Wireless Module Type, page 252, is set to B820 Inovonics Wireless,
the control panel is limited to 350 wireless devices not including repeaters. Wirelessis only a
valid option if the number of points with point Source, page 176set to Wirelessplus the
number of users assigned a valid key fob RF ID is less than 350. Both the control panel and
RPS enforce this restriction. Note, point Sourceis used instead of RF ID as the installer might
have assigned several points to wireless without adding any RF IDs.
When the point Source is configured to Wireless then the RFID will be set to 0.
If an SDI2 communication device is allocated for automation communication, then it cannot be
used for central station nor for RPS communication.
NOTE: To expand or collapse the list of Point numbers, use the arrows at the top of the RPS
screen.
RPS Menu Location
Points > Point Assignments > RFID (B820 Inovonics Wireless)
10.2 Cross Point Parameters
10.2.1 Cross Point Timer
Default: 20