178 en | Points Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
RPS Menu Location
Points > Point Assignments > Index
10.1.5 Profile (Index) Description
Default:
– Point 1: Smoke Detector
– Point 2: Part On: Delay
– Point 3: Part On: Delay
– Point 4: Interior: Follower
– Point 5: Interior: Follower
– Point 6: Part On: Instant
– Point 7: Part On: Instant
– Point 8: 24-Hour Instant Open/Short
Selections: No selections – this field cannot be edited by the user
This field displays a description of the point index that is entered in the Index field. It is a
reference field only and the information displayed in it is not sent to the control panel.
NOTE: To expand or collapse the list of Point numbers, use the arrows at the top of the RPS
screen.
RPS Menu Location
Points > Point Assignments > Description
10.1.6 Area
Default:1
Selections:
– B9512G - 1 to 32
– B8512G - 1 to 8
Enter the area number you want to assign the point to.
NOTE: To expand or collapse the list of Point numbers, use the arrows at the top of the RPS
screen.
RPS Menu Location
Points > Point Assignments > Area
10.1.7 Debounce
Default: 820 ms
Selections:
– 410 ms
– 820 ms
– 1.23 s
– 1.64 s
– 2.05 s
– 2.46 s
– 2.87 s
– 3.28 s
– 3.69 s
– 4.10 s
– 4.51 s
– 4.92 s
– 5.33
– 5.74