190 en | Points Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
Notice!
Control panel and B208 Octo-input firmware requirements for Dual EOL
To use the Dual EOL Circuit style, verify the control panel firmware is v3.01 or greater.
If you are using a B208 Octo-input Module, verify the module firmware is v2.1.1 or greater.
Custom Function Point Type, No EOL Circuit Style, Point Response Selections
Armed
State
Circuit
State 0 1 2 3 4 5 6 7 8 9 A B C D E F
Armed Fault T CF CF CF CF CF CF CF CF CF CF CF T B
Disarmed Fault CF T CF CF CF CF CF CF CF CF CF CF T B
Key: CF = control panel executes custom function on transition to circuit state. T = trouble, blank = no response
When the point circuit state changes the control panel responds by activating a custom
function.
Point Response for B820 SDI2 Inovonics Interface Module
When point Source is set to Wireless and a B820 SDI2 Inovonics Interface Module is used,
wireless points:
– send Short for point fault (regardless of sensor loop open/short state)
– send Open for a tamper event (enclosure cover removed)
Point Response for B810 RADION receiver SD
When point Source is set to wireless and a B810 RADION receiver SD module is used, wireless
points:
– send Open or Short for point fault (the electrical state of the sensor loop)
– send Short for the reed switch (magnet not present)
– send Tamper for a tamper event (enclosure cover removed)
RPS Menu Location
Points > Point Indexes > Point Type / Response / Circuit Style
Further information
Point Type, page 184
Circuit Style, page 202
10.3.6 Entry Delay
Default: 30 seconds
Selections:5 - 600 seconds (5-second increments)
This parameter sets the amount of entry delay time that a user has after faulting a controlled
point (Part On, Interior or Interior Follower) with a delayed response (D) (Point Response,
page 184) of 4, 5, 6, 7, or 8.
Notice!
To comply with UL standards, the total amount of time entered in Entry Delay and Alarm
Abort, page 199 must not exceed 1 minute.
Notice!
To comply with SIA CP-01 False Alarm Reduction, set this parameter between 30 and 240
seconds for all point indexes. Refer to SIA CP-01 Verification for more information.