160 en | User Configuration Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
9.4.6 Part On, Instant
Default:
Authority Levels 1-4: Enabled (E)
Authority Levels 5-15: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
This parameter allows users to turn the system Part On, Instant (arm all Part On (perimeter)
points with no exit and no entry delay time in areas within the scope of the keypad being
used, and that correspond to the user's Authority Level).
If a user uses Command 2, Part On, Instant only arms the area the keypad is assigned to.
If a user uses the Remote Security Control app (RSC) to turn the system Part On, Instant, the
areas that correspond to the user’s Authority Level are armed.
RPS Menu Location
User Configuration > Authority Levels > Part On Instant
9.4.7 Part On, Delay
Default:
Authority Levels 1-4: Enabled (E)
Authority Levels 5-15: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
This parameter allows users to turn the system Part On, Delay (arm all Part On (perimeter)
points with entry exit and entry delay time in areas within the scope of the keypad being used,
and that correspond to the user's Authority Level).
If a user uses Command 3, Part on, Delay only arms the area the keypad is assigned to.
If a user uses the Remote Security Control app (RSC) to turn the system Part On, Delay, the
areas that correspond to the user’s Authority Level are armed.
RPS Menu Location
User Configuration > Authority Levels > Part On Delay
9.4.8 Watch Mode
Default:
Authority Levels 1-3, 15: Enabled (E)
Authority Levels 4-14: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
This parameter allows the user with this authority level to initiate the watch mode in the area
to which this is keypad assigned.
Authority Level 15 is reserved for the Service Passcode (User 0). You cannot change any
settings in the Authority Level 15 column.
RPS Menu Location
User Configuration > Authority Levels > Watch Mode