18 en | Compliance Settings Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
2 Compliance Settings
2.1 SIA CP-01 Verification
Default:No
Selections:
– Yes. Check the following parameters for SIA CP-01 compliance:
– Duress Type, page 74
– Alarm Bell, page 133
– Exit Delay Time, page 94
– Burg Time, page 100
– Exit Delay Warning, page 107
– Entry Delay Warning, page 107
– Entry Delay, page 190
– Passcode Length, page 79
– Remote Warning, page 81
– Swinger Bypass Count, page 80
– Cancel Reports, page 75
– Two Man Rule?, page 98 ?
– Early Ambush?, page 99?
– All On, Instant, page 159
– Part On, Instant, page 160
– Passcode Enter Function, page 113
– No. Do not check parameters for SIA CP-01 compliance.
This parameter specifies whether or not this control panel requires SIA CP-01 False Alarm
Reduction compliance.
If RPS receives programming data from the control panel that is not SIA CP-01-compliant, the
SIA CP-01 Compliance window opens. Parameters that are out of compliance are listed.
Making the parameters SIA CP-01 compliant:
1. Enter a value under the Desired Value column that is between the compliant SIA minimum
and maximum values.
2. Select one of the following options:
– Set the SIA CP-01 Verification to No and store the existing data in this account.
– Leave the SIA CP-01 Verification Parameter to Yes and store the data in the Desired
Value field in this account.
If a control panel account contains parameters that do not comply with SIA CP-01, and you
retrieve that data using the Unattended Mode feature, RPS stores the non-compliant data
regardless of the SIA CP-01 parameter's setting.