60 en | Panel Wide Parameters Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
– SDI2 address 2 Destination 3
– SDI2 address 2 Destination 4
This parameter sets the Primary Destination Device for a Route Group. The control panel uses
the device to send reports to the central station receiver.
The Primary Destination Device selections pair a communicator (onboard IP communicator,
plug-in cellular communicator, plug-in phone communicator, or SDI2 module) and a
destination (Network Address, page 62, or Phone and Phone Parameters, page 28)
RPS Menu Location
Panel Wide Parameters > Communicator > Primary Destination Device
Further information
For more information on how the control panel sends reports, refer to Reporting Overview,
page 44 and Communicator, overview, page 58.
3.10.2 Backup Destination Device
Default:No Device
Selections:
– No Device
– Onboard IP Destination 1
– Onboard IP Destination 2
– Onboard IP Destination 3
– Onboard IP Destination 4
– Plug-in Cellular Destination 1
– Plug-in Cellular Destination 2
– Plug-in Cellular Destination 3
– Plug-in Cellular Destination 4
– Plug-in Phone Destination 1
– Plug-in Phone Destination 2
– Plug-in Phone Destination 3
– Plug-in Phone Destination 4
– SDI2 address 1 Destination 1
– SDI2 address 1 Destination 2
– SDI2 address 1 Destination 3
– SDI2 address 1 Destination 4
– SDI2 address 2 Destination 1
– SDI2 address 2 Destination 2
– SDI2 address 2 Destination 3
– SDI2 address 2 Destination 4
This parameter sets the Backup Destination Device for a Route Group. The control panel uses
the backup device to send reports to the central station receiver when the primary device
fails.
The Backup Destination Device selections pair a communicator (onboard IP communicator,
plug-in cellular communicator, plug-in phone communicator, or SDI2 module) and a
destination (Network Address, page 62, or Phone and Phone Parameters, page 28)
Do not select the same destination device for both Primary Destination Device and Backup
Destination Device for a Route Group.
RPS Menu Location
Panel Wide Parameters > Communicator > Backup Destination Device