Control Panel Hardware switch settings | en 257
Bosch Security Systems, Inc. Program Entry Guide 2017.03 | 09 | F.01U.303.998
Address Switches
1 2 3 4 5 6
8 OFF OFF OFF ON OFF OFF
9 ON OFF OFF ON OFF OFF
10 OFF ON OFF ON OFF OFF
11 ON ON OFF ON OFF OFF
12 OFF OFF ON ON OFF OFF
13 ON OFF ON ON OFF OFF
14 OFF ON ON ON OFF OFF
15 ON ON ON ON OFF OFF
16 OFF OFF OFF OFF ON OFF
17 ON OFF OFF OFF ON OFF
18 OFF ON OFF OFF ON OFF
19 ON ON OFF OFF ON OFF
20 OFF OFF ON OFF ON OFF
21 ON OFF ON OFF ON OFF
22 OFF ON ON OFF ON OFF
23 ON ON ON OFF ON OFF
24 OFF OFF OFF ON ON OFF
25 ON OFF OFF ON ON OFF
26 OFF ON OFF ON ON OFF
27 ON ON OFF ON ON OFF
28 OFF OFF ON ON ON OFF
29 ON OFF ON ON ON OFF
30 OFF ON ON ON ON OFF
31 ON ON ON ON ON OFF
32 OFF OFF OFF OFF OFF ON
B92x Two-line Keypad / B93x ATM Style Keypad address switch settings
Set the address switches per the control panel configuration. If multiple SDI2 keypads reside
on the same system, each SDI2 keypad must have a unique address. For single-digit addresses
1 through 9, set the tens switch to 0. The figure below shows the address switch setting for
address 1.